ESPECIFICACIONES TECNICAS
Model | MX-12FAM | |
Detection system | Passive Infrared and Mocrowave | |
Microwave frequency and power | 24.150 to 24.250GHz 12.7dBm e.i.r.p. | |
Coverage | horizontal detection Angle: 180°, Detection distance: 12m (40ft) Horizontal zone: 14 zones, Downward zone: 14 zones |
|
PIR area adjustment | Detection distance : 2 to 12m (10′ to 40′) [10 ranges]) (by adjusting vertical angle of downward curtain) Left and right individual adjustment possible |
|
Supply voltage | 9 to 28V DC (non-polarity) | |
Current consumption | 30mA MAX. | |
Alarm output (1) | RIGHT + LEFT | Dry contact relay output N.C./N.O. selectable Contact capacity : 30V (AC/DC), 0.2A MAX. (Resistive load) Contact operation : Detection time (+2sec) |
RIGHT | ||
Alarm output (2) | LEFT | Dry contact relay output N.C./N.O. selectable Contact capacity : 30V (AC/DC), 0.2A MAX. (Resistive load) Contact operation : Detection time (+2sec) |
EXTERNAL OUTPUT | Dry contact relay output N.C. Contact capacity : 30V (AC/DC), 0.2A MAX. (Resistive load) Contact operation : Detection time (+30sec latch time) |
|
Trouble output | Dry contact relay output N/C • Contact capacity : 30V (AC/DC) 0.2A Max. (Resistive load) (Masking detection / Low supply voltage / Self diagonosis error) |
|
Tamper output | Dry contact relay output N/C • Contact capacity : 30V (AC/DC) 0.1A Max. (Resistive load) (Cover tamper / When back tamper is detected) |
|
Operation LED | Red LED • Warm-up (Blinks) • Alarm detection (Lights approx.2sec only Walk test) • Masking detection (Blinks rapidly) • Low supply voltage (Blinks slowly) • Self diagonosys error (Lights continuously) • Microwave alarm detection (Lights max.2sec only for Walk test) |
|
Pulse count | 1 / 3 times (selectable with DIP switch) | |
PIR Sensitivity adjustment | 60% / 80% / 100% / 120% (selectable with DIP switch, left and right set individually) |
|
Microwave range adjustment | Short / Long (selectable with DIP switch, left and right sensors individually) |
|
Functions | Anti-Masking, Microwave environment, Back Tamper, Trouble alarm, Low voltage monitoring, Anti-masking Environmental level | |
Connection | Terminals | |
Ambient temperature | -25°C to +60°C (-13°F to +140°F) | |
Mounting position | Indoor / Outdoor | |
Ingress protection | IP55 (Wall Mount) | |
Weight | 400g (14.2oz) | |
Appearance | Body : resin (white) / Lens : resin (white) | |
Optional | Pole attachment : BP-32 |